Monitoring biodiversity in libraries: a pilot study and perspectives for indoor air quality
PDF

Keywords

Library
indoor air quality
microflora
NGS
monitoring

Abstract

Indoor Air Quality (IAQ) in libraries is influenced by the presence of specific factors which can impact on both paper storage as well as people health. Microclimatic conditions induce and support a biodiversity pattern involving environmental and anthropic microorganisms. We used a multidisciplinary monitoring model to characterize microflora biodiversity by Next Generation Sequencing (NGS). Biodiversity indexes were adapted to evaluate anthropic vs environmental pollution by combining microbial load (H), species representativeness (EH), human/environmental pollution ratio (SA) to better characterize the NGS output and acquire synthetic information on Indoor Air Microbial Biodiversity (IAMB). Results indicate a frequently low microbial load (IGCM/m3 <1000) characterized by different species (n=102), including several cellulose metabolizing bacteria. Workers and visitors appeared a relevant source of microbial contamination. Air biodiversity assayed by NGS seems a promising marker for studying IAQ.

https://doi.org/10.15167/2421-4248/jpmh2017.58.3.730
PDF

References

Caselli M, De Gennaro G, Saracino MR, Tutino M. Indoor contaminants from newspapers: VOC emission in newspaper stands. Environ Res. 2009;109:149–57. doi:10.1016/j.envres.2008.10.011.

___________________________________________

Haleem Khan AA, Mohan Karuppayil S. Fungal pollution of indoor environments and its management. Saudi J Biol Sci. 2012;19:405-26. doi: http://dx.doi.org/10.1016/j.sjbs.2012.06.002.

___________________________________________

Kalwasińska et al. A, Burkowska A, Wilk I. Microbial air contamination in indoor environment of a university library. Ann Agric Environ Med. 2012;19:25-9.

___________________________________________

Pegas PN, Alves CA, Evtyugina MG, Nunes T, Cerqueira M, Franchi M, Pio CA, Almeida SM, Freitas MC. Indoor air quality in elementary schools of Lisbon in spring. Environ Geochem Health. 2011;33:455-68. doi: 10.1007/s10653-010-9345-3.

___________________________________________

Meadow JF, Altrichter AE, Kembel SW, Kline J, Mhuireach G, Moriyama M, Northcutt D, O'Connor TK, Womack AM, Brown GZ, Green JL, Bohannan BJM. Indoor airborne bacterial communities are influenced by ventilation, occupancy, and outdoor air source. Indoor Air. 2014;24: 41-8. doi:10.1111/ina.12047.

___________________________________________

Hospodsky D, Qian J, Nazaroff WW, Yamamoto N, Bibby K, Rismani-Yazdi H, Peccia J. Human occupancy as a source of indoor airborne bacteria. PLoS ONE. 2012;7:34867. doi:10.1371/journal.pone.0034867.

___________________________________________

Qian J, Hospodsky D, Yamamoto N, Nazaroff WW, Peccia J. Size-resolved emission rates of airborne bacteria and fungi in an occupied classroom. Indoor Air. 2012;22: 339-51. doi:10.1111/j.1600-0668.2012.00769.x

___________________________________________

WHO. World Health Organization. 2009. Guidelines for indoor air quality: dampness and mould. Copenhagen, Denmark: World Health Organization; [Accessed on 24th November, 2013]. Available from: http://www. euro.who.int/__data/assets/pdf_file/0017/43325/E92645.pdf.

___________________________________________

Graudenz GS, Oliveira CH, Tribess A, Mendes C Jr, Latorre MR, Kalil J. Association of air conditioning with respiratory symptoms in office workers in tropical climate. Indoor Air. 2005;15:62-6. doi: 10.1111/j.1600-0668.2004.00324.x.

___________________________________________

Rella R, Sturaro A, Vianello A. Incorrect installation and use of materials as the cause of a severe air pollution incident in a school building. Sci. Total Environ. 2014;487: 255-59. doi:http://dx.doi.org/10.1016/j.scitotenv.2014.04.031

___________________________________________

Wamedo SA, Ede PN, Chuku A. Interaction between building design and indoor airborne microbial load in Nigeria. Asian J Biol Sci. 2012;5:183-91. doi: 10.3923/ajbs.2012.183.191.

___________________________________________

Righi E, Aggazzotti G, Fantuzzi G, Ciccarese V, Predieri G. Air quality and well-being perception in subjects attending university libraries in Modena (Italy). Sci. Total Environ. 2002;286:41-50. doi:10.1016/S0048-9697(01)00960-3.

___________________________________________

Brandt-Rauf PW, Andrews LR, Schwarz-Miller J. Sick-hospital syndrome. J Occup Med. 1991;33:737-9. doi: 10.1097/00043764-199106000-00017.

___________________________________________

Burge PS. Sick building syndrome. Occup Environ Med. 2004; 61:185-90.

___________________________________________

Sauni R, Verbeek JH, Uitti J, Jauhiainen M, Kreiss K, Sigsgaard T. Remediating buildings damaged by dampness and mould for preventing or reducing respiratory tract symptoms, infections and asthma. Cochrane Database Syst Rev. 2015;25:2. doi: 10.1002/14651858.CD007897.pub2.

___________________________________________

Abbritti G. Indoor environments, work and health. G Ital Med Lav Ergon. 2004;26:346-52.

___________________________________________

Jantunen M, Oliveira Fernandes E, Carrer P, Kephalopoulos S. Promoting actions for healthy indoor air (IAIAQ). European Commission Directorate General for Health and Consumers. Luxembourg; 2011.

___________________________________________

Kelley ST, Gilbert JA. Studying the microbiology of the indoor environment. Genome Biol. 2013;14:202. doi:10.1186/gb-2013-14-2-202.

___________________________________________

Shanker A. 2012. Genome research in the cloud. OMICS. 16:422-8. doi: 10.1089/omi.2012.0001.

___________________________________________

Giampaoli S, Berti A, Valeriani F, Gianfranceschi G, Piccolella A, Buggiotti L, Rapone C, Valentini A, Ripani L, Romano Spica V. Molecular identification of vaginal fluid by microbial signature. Forensic Sci Int Genet. 2012;6: 559-64. doi: 10.1016/j.fsigen.2012.01.005.

___________________________________________

Giampaoli S, Chillemi G, Valeriani F, Lazzaro D, Borro M, Gentile G, Simmaco M, Zanni G, Berti A, Romano Spica V. The SNPs in the human genetic blueprint era. N Biotechnol. 2013;30:475-84. doi: 10.1016/j.nbt.2012.11.015.

___________________________________________

Mansi A, Amori I, Marchesi I, Marcelloni AM, Proietto AR, Ferranti G, Magini V, Valeriani F, Borella P. Legionella spp. survival after different disinfection procedures: comparison between conventional culture, qPCR and EMA-qPCR.Microchem J 2014;112; 65-9. doi:http://dx.doi.org/10.1016/j.microc.2013.09.017.

___________________________________________

Valeriani F, Protano C, Gianfranceschi G, Cozza P, Campanella V, Liguori G, Vitali M, Divizia M, Romano Spica V. Infection control in healthcare settings: perspectives for mfDNA analysis in monitoring sanitation procedures. BMC Infect Dis. 2016;16:394. doi: 10.1186/s12879-016-1714-9.

___________________________________________

Valeriani F, Giampaoli S, Buggiotti L, Gianfranceschi G, Romano Spica V. Molecular enrichment for detection of S. aureus in recreational waters. Water Sci Technol. 2012;66(11):2305-10. doi:10.2166/wst.2012.435.

___________________________________________

Ahmad I, Ahmad F, Pichtel J. Microbes and Microbial Technology: agricultural and environmental applications. New York: Ed. Springer; 2011.

___________________________________________

Fenech A, Strlič M, KraljCigić I, Levart A, Gibson LT, De Bruin G, Ntanos K. Volatile aldehydes in libraries and archives. Atmos Environ. 2010;44:2067–73. doi:http://dx.doi.org/10.1016/S0048-9697(96)05335-1.

___________________________________________

Pasquarella C, Saccani E, Sansebastiano GE, Ugolotti M, Pasquariello G, Albertini R. Proposal for a biological environmental monitoring approach to be used in libraries and archives. Ann Agric Environ Med. 2012;19:209-12.

___________________________________________

Fantuzzi G, Aggazzotti G, Righi E, Cavazzuti L, Predieri G, Francaschelli A. Indoor air quality in the university libraries of Modena, Italy. Sci. Total Environ. 1996;193:49-56.

___________________________________________

Lee CM, Kim YS, Nagajyoti PC, Park W, Kim KY. Pattern classification of volatile organic compounds in various indoor environments. Water Air Soil Pollut. 2011;215:329-38. doi: 10.1111/j.1600-0668.1997.t01-2-00007.x.

___________________________________________

Adam G, Pont U, Mahdavi A. Evaluation of thermal environments and indoor air quality in university libraries in Vienna. Adv Mat Res.2014;899:315-20. doi:10.4028/www.scientific.net/AMR.899.315

___________________________________________

Borrego S, Guiamet P, Gomez de Saravia S, Batistini P, Garcia M, Lavin P, Perdomo I. The quality of air at archives and the biodeterioration of photographs. Int. Biodeterior. Biodegradation. 2010; 64:139-45. doi: 10.1016/j.ibiod.2009.12.00.

___________________________________________

Zielińska-Jankiewicz K, Kozajda A, Piotrowska M, Szadkowska-Stańczyk I. Microbiological contamination with molds in work environment in libraries and archive storage facilities. Ann Agric Environ Med. 2008;15:71-8.

___________________________________________

Dacarro C, Picco AM, Grisoli P, Rodolfi M. Determination of aerial microbiological contamination in scholastic sports environments. J. Appl. Microbiol. 2003;95:904-12. doi: 10.1046/j.1365-2672.2003.02044.x.

___________________________________________

White TJ, Bruns T, Lee S, Taylor J. PCR Protocols, a Guide to Methods and Applications: Amplification and direct sequencing of fungal ribosomal RNA genes for phylogenetics. New York:Academic Press. p 315-322; 1990.

___________________________________________

Kittelmann S, Seedorf H, Walters WA, Clemente JC, Knight R, Gordon JI, Janssen PH. Simultaneous amplicon sequencing to explore co-occurrence patterns of bacterial, archaeal and eukaryotic microorganisms in rumen microbial communities. PLoS One. 2013;8:47879. doi:http://dx.doi.org/10.1371/journal.pone.0047879.

___________________________________________

Wang Q, Garrity GM, Tiedje JM, Cole JR. Naive Bayesian classifier for rapid assignment of rRNA sequences into the new bacterial taxonomy. Appl. Environ. Microbiol. 2007;3:5261-7. doi:10.1128/AEM.00062-07.

___________________________________________

Colwell, R. K., A. Chao, N. J. Gotelli, S.-Y. Lin, C. X. Mao, R. L. Chazdon, and J. T. Longino. Models and estimators linking individual-based and sample-based rarefaction, extrapolation, and comparison of assemblages. Journal of Plant Ecology. 2012;5:3-21. doi: https://doi.org/10.1093/jpe/rtr044.

___________________________________________

Schloss PD, Westcott SL, Ryabin T, Hall JR, Hartmann M, Lesniewski RA, Oakley BB, Parks DH, Robinson CJ, Sahl JW, Stres B, Thallinger GG, Van Horn DJ and Weber CF. Introducing mothur: Opensource, platform-independent, community-supported software for describing and comparing microbial communities. Appl. Environ. Microbiol. 2009;5:7537-41. doi: 10.1128/AEM.01541-09.

___________________________________________

ACGIH. American Conference of Governmental Industrial Hygienists. Industrial Ventilation: A Manual of Recommended Practice. Cincinnati, OH; 1995.

___________________________________________

CEC. Commission of the European Communities (EU). Indoor air quality and its impact on man. Report No. 12. Biological particles in indoor environments. Luxembourg; 1993.

___________________________________________

Hayleeyesus SF, and Manaye AM. Microbiological quality of indoor air university libraries. Asian Pac J Trop Biomed. 2014;1:312-17. doi:10.12980/APJTB.4.2014C807.

___________________________________________

Brandi G, Sisti M, Paparini A, Gianfranceschi G, Schiavano GF, De Santi M, Santoni D, Magini V, Romano-Spica V. Swimming pools and fungi: an environmental epidemiology survey in Italian indoor swimming facilities. Int J Environ Health Res. 2007;17:197-206. doi:10.1080/09603120701254862.

___________________________________________

Giampaoli S, Berti A, Di Maggio RM, Pilli E, Valentini A, Valeriani F, Gianfranceschi G, Barni F, Ripani L, Romano Spica V. The environmental biological signature: NGS profiling for forensic comparison of soils. Forensic Sci. Int. 2014;240:41-7. doi:http://dx.doi.org/10.1016/j.forsciint.2014.02.028

___________________________________________

Maron PA, Lejon DPH, Carvalho E, Bizet K, Lemanceau P, Ranjard L, Mougel C. Assessing genetic structure and diversity of airborne bacterial communities by DNA fingerprinting and 16S rDNA clone library. Atmos. Environ. 2005;39:3687-95. doi:http://dx.doi.org/10.1016/j.atmosenv.2005.03.002.

___________________________________________

Begon M, Harper JL, Townsend CR. Ecology: from individuals to ecosystems. Oxford: Ed Blackwell Scientific Publications; 1986.

___________________________________________

Gut IG. New sequencing technologies. Clin Transl Oncol. 2013;15:879-81. doi: 10.1007/s12094-013-1073-6.

___________________________________________

Jost L. The Relation between Evenness and Diversity. Diversity. 2010;2:207-32. doi:10.3390/d2020207.

___________________________________________

Hill TC, Walsh KA, Harris JA, Moffett BF. 2003. Using ecological diversity measures with bacterial communities. FEMS Microbiol. Ecol. 43:1-11.

___________________________________________

Van rensburg JJ, Lin H, Gao X, Toh E, Fortney KR, Ellinger S, Zwickl B, Janowicz DM, Katz BP, Nelson DE, Dong Q, Spinola SM. The Human Skin Microbiome Associates with the Outcome of and Is Influenced by Bacterial Infection. MBio. 2015;6:01315-15. doi:10.1128/mBio.01315-15.

___________________________________________

Bajpai P. Pulp and Paper Industry: Microbiological Issues in Papermaking. Ed Elsevier; 2015.

___________________________________________

Li TC, Ambu S, Mohandas K, Wah MJ, Sulaiman LH, Murgaiyah M. Bacterial constituents of indoor air in a high throughput building in the tropics. Trop Biomed. 2014;31:540-56.

___________________________________________

Johansen C, Falholt P, Gram L. Enzymatic removal and disinfection of bacterial biofilms. Appl. Environ. Microbiol. 1997;63:3724-28. doi: 0099-2240/97/$04.0010.

___________________________________________

Lessie TG, Phibbs PV Jr. Alternative pathways of carbohydrate utilization in pseudomonads. Annu. Rev. Microbiol. 1984;38:359-388. doi: 10.1146/annurev.mi.38.100184.002043.

___________________________________________

Nandalal P, Somashekar RK. Prevalence of Staphylococcus aureus and Pseudomonas aeruginosa in indoor air flora of a district hospital, Mandya, Karnataka. J Environ Biol. 2007;28:197-200.

___________________________________________

Cetinkaya Z, Fidan F, Unlu M, Hasenekoglu I, Tetik L, Demirel R. Assessment of indoor air fungi in Western-Anatolia, Turkey. Asian Pac. J. Allergy Immunol. 2005;23:87-92.

___________________________________________

Lonc E, Kinga P, Kiewra D, Szczepańska A. Firling CE. Quantitative assessment of mycological air pollution in selected rooms of residential and dormitory housing facilities. Ann Parasitol. 2013;59:183-17.